90..132Vac / 184..265Vac , 47…63Hz , 250…375Vdc
Compensation 2V per lead load
tive electrical separation
protective electrical separation
protective electrical separation
, thermal shutdown with auto recovery
(+70°C, metering distance 10mm)
Controlled fan (manufacturer EBM
Meantime By Failure (MTBF)
¹)
¹) option
Ordering Information:
Output Type (DIN-Rail standard) Part Number Option Part Number
0...18V HSEUreg10001.18T 304.1053.001CA Backplate kit
(wallmount)
220.1002.001CA
0...30V HSEUreg10001.30T 304.1053.002CA
0...50V HSEUreg10001.50T 304.1053.003CA ADTW201
DC-repeater
304.1090.001CA
0...90V HSEUreg10001.90T 304.1053.004CA
0...130V HSEUreg10001.130T 304.1053.005CA 4..20mA option
Ad 420 to the type number example:
HSEUreg04801.15T420
0...180V HSEUreg10001.180T 304.1053.006CA
0...240V HSEUreg10001.240T 304.1053.007CA Screw terminal plug 3520037 2pol. LS5,08 (package=10pcs)